Development and Validation of an Automated Step Ergometer

Content

Title variants

Languages of publication

EN

Abstracts

EN
Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject’s height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60-180 s; 116-160 bpm, respectively). Data was compared with the student’s t test and ANOVA; correlations were tested with Pearson’s r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach’s alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness.

Publisher

Year

Volume

43

Issue

1

Pages

113-124

Physical description

Dates

published
1 - 12 - 2014
online
11 - 12 - 2014

Contributors

  • Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil
  • Physical Education Post-graduate Associate Program, Federal University of Paraíba, João Pessoa, Brasil
  • Laboratório de Cineantropometria e Desempenho Humano, Núcleo de Pesquisa em Ciências do Movimento Humano Universidade Federal da Paraíba, Sala 06, Castelo Branco, CEP: 58051-900, João Pessoa-PB, Brazil. Phone number: +55 83 99500577
  • Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil
  • Physical Education Post-graduate Associate Program, Federal University of Paraíba, João Pessoa, Brasil
  • Laboratory of Kinesiology and Biomechanics, Integrated Colleges of Patos, Patos, Brasil.
  • Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil
  • Physical Education Post-graduate Associate Program, Federal University of Paraíba, João Pessoa, Brasil
  • Physical Education Post-graduate Program, Federal University of Rio de Janeiro, Rio de Janeiro, Brasil
  • Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil.
  • Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil
  • Physical Education Post-graduate Associate Program, Federal University of Paraíba, João Pessoa, Brasil.
  • Federal Institute of Education, Science and Technology of Paraiba, João Pessoa, Brazil.
  • Methodist University of Piracicaba, Piracicaba, Brazil.

References

  • Anton SD, Duncan GE, Limacher MC, Martin AD, Perri MG. How much walking is needed to improve cardiorespiratory fitness? An examination of the 2008 physical activity guidelines for americans. Res Q Exerc Sport, 2011; 82: 365-370
  • Ashley CD, Smith JF, Reneau PD. A modified step test based on a function of subjects' stature. Percept Mot Skills, 1997; 85: 987-993[Crossref]
  • Astorino TA, Willey J, Kinnahan J, Larsson SM, Welch H, Dalleck LC. Elucidating determinants of the plateau in oxygen consumption at VO2max. Br J Sports Med, 2005; 39: 655-660[Crossref]
  • Balderrama C, Ibarra G, De La Riva J, López S. Evaluation of three methodologies to estimate the VO2max in people of different ages. Appl Ergon, 2010; 42: 162-168[WoS][Crossref]
  • Bernasconi SM, Tordi N, Ruiz J, Parratte B. Changes in oxygen uptake, shoulder muscles activity, and propulsion cycle timing during strenuous wheelchair exercise. Spinal Cord, 2007; 45: 468-474[PubMed][Crossref][WoS]
  • Bruce RA. Evaluation of functional capacity and exercise tolerance of cardiac patients. Mod Concepts Cardiovasc Dis, 1956; 25: 321-326
  • Currell K, Jeukendrup AE, Validity, reliability and sensitivity of measures of sporting performance. Sports Med, 2008; 38: 297-316[Crossref][PubMed][WoS]
  • Francis K, Brasher J. A height-adjusted step test for predicting maximal oxygen consumption in males. J Sports Med Phys Fitness, 1992; 32: 282-287[PubMed]
  • Gaskill SE, Rice T, Bouchard C, Gagnon J, Rao DC, Skinner JS, Wilmore JH, Leon AS. Familial resemblance in ventilatory threshold: the HERITAGE Family Study. Med Sci Sports Exerc, 2001; 33: 1832-1840[Crossref][PubMed]
  • Hansen D, Jacobs N, Bex S, D’Haene G, Dendale P, Claes N. Are fixed-rate step tests medically safe for assessing physical fitness? Eur J Appl Physiol, 2011; 111: 2593-2599[PubMed][WoS][Crossref]
  • Ingham SA, Pringle JS, Hardman SL, Fudge BW, Richmond VL. Comparison of step-wise and ramp-wise incremental rowing exercise tests and 2000-m rowing ergometer performance. Int J Sports Physiol Perform, 2013; 8: 123-129
  • Kendall KL, Smith AE, Fukuda DH, Dwyer TR, Stout JR. Critical velocity: a predictor of 2000-m rowing ergometer performance in NCAA D1 female collegiate rowers. J Sports Sci, 2011; 29: 945-950[PubMed][Crossref]
  • Kjelkenes I, Thorsen E. Anticipating maximal or submaximal exercise: no differences in cardiopulmonary responses. Clin Physiol Funct Imaging, 2010; 30: 333-337[PubMed][WoS][Crossref]
  • Kline GM, Porcari JP, Hintermeister R, Freedson PS, Ward ANN, Mccarron RF, Ross J, Rippe JM. Estimation of VO2max from a one-mile track walk, gender, age, and body weight. Med Sci Sports Exerc, 1987; 19: 253-259
  • Laskin JJ, Slivka D, Frogley M. A cadence based sub-maximal field test for the prediction of peak oxygen consumption in elite wheelchair basketball athletes. JEPonline, 2004; 7: 8-18
  • Lochte L, Angermann M, Larsson B. Cardiorespiratory fitness of asthmatic children and validation of predicted aerobic capacity. Clin Respir J, 2009; 3: 42-50[WoS][Crossref][PubMed]
  • Machado FA, Guglielmo LGA, Denadai BS. Running speed associated with maximal oxygen uptake in boys aged 10 to 15 years. Rev Bras Med Esporte, 2002; 8: 1-6
  • Mahon AD, Marjerrison AD, Lee JD, Woodruff ME, Hanna LE. Evaluating the prediction of maximal heart rate in children and adolescents. Res Q Exerc Sport, 2010; 81: 466-471[Crossref][WoS]
  • Manero R, Manero JM. Dos alternativas para el estudio y promoción de la capacidad física de los trabajadores. Mapfre Seguridad, 1991; 44: 105-112
  • Millet GP, Vleck VE, Bentley DJ. Physiological differences between cycling and running: lessons from triathletes. Sports Med, 2009; 39: 179-206[WoS][PubMed][Crossref]
  • Myers J, Arena R, Franklin B, Pina I, Kraus WE, McInnis K, Balady GJ. Recommendations for clinical exercise laboratories: a scientific statement from the American Heart Association. Circulation, 2009; 119: 3144-3161[PubMed][Crossref]
  • Nakhostin-Roohi B, Niknam Z. BMI, fat percentage and VO2max in college female staff. J Sports Med Phys Fitness, 2008; 48: 211-216
  • Nemeth BA, Carrel AL, Eickhoff J, Clark RR, Peterson SE, Allen DB. Submaximal treadmill test predicts V̇O2max in overweight children. J Pediatr, 2009; 154: 677-681[WoS][Crossref]
  • Noonan V, Dean E. Submaximal exercise testing: clinical application and interpretation. Phys Ther, 2000; 80: 782-807[PubMed]
  • Rankovic G, Mutavdzic V, Toskic D, Preljevic A, Kocic M, Nedin Rankovic G, Damjanovic N. Aerobic capacity as an indicator in different kinds of sports. Bosn J Basic Med Sci, 2010; 10: 44-48
  • Siconolfi SF, Cullinane EM, Carleton RA, Thompson PD. Assessing VO2max in epidemiologic studies: modification of the Astrand-rhyming test. Med Sci Sports Exerc, 1982; 14: 335-338
  • Siconolfi SF, Garber CE, Lasater TM, Carleton RA. A simple, valid step test for estimating maximal oxygen uptake in epidemiologic studies. Am J Epidemiol, 1985; 121: 382-390[PubMed]
  • Weiglein L, Herrick J, Kirk S, Kirk EP. The 1-mile walk test is a valid predictor of VO(2max) and is a reliable alternative fitness test to the 1.5-mile run in U.S. Air Force males. Military Medicine, 2011; 176: 669-673
  • Wicks JR, Oldridge NB, Nielsen LK, Vickers CE. Heart rate index - a simple method for prediction of oxygen uptake. Med Sci Sports Exerc. 2011; 43: 2005-2012 [WoS][PubMed]

Document Type

Publication order reference

Identifiers

YADDA identifier

bwmeta1.element.-psjd-doi-10_2478_hukin-2014-0096
JavaScript is turned off in your web browser. Turn it on to take full advantage of this site, then refresh the page.