High Power Laser Laboratory at the Institute of Plasma Physics and Laser Microfusion: equipment and preliminary research

Content
Title variants
Languages of publication
EN
Abstracts
EN
The purpose of this paper is to present the newly-opened High Power Laser Laboratory (HPLL) at the Institute of Plasma Physics and Laser Microfusion (IPPLM). This article describes the laser, the main laboratory accessories and the diagnostic instruments. We also present preliminary results of the first experiment on ion and X-ray generation from laser-produced plasma that has been already performed at the HPLL.
Publisher
Journal
Year
Volume
60
Issue
2
Pages
245-248
Physical description
Dates
published
1 - 6 - 2015
accepted
19 - 11 - 2014
online
22 - 6 - 2015
received
6 - 10 - 2014
References
  • 1. Gibbon, P. (2007). Short pulse laser interactions with matter. London: Imperial College Press.
  • 2. Macchi, M., Borghesi, M., & Passoni, M. (2013). Ion acceleration by superintense laser-plasma interaction. Rev. Mod. Phys., 85, 751–793. DOI: 10.1103/RevModPhys.85.751.[WoS][Crossref]
  • 3. Atzeni, A., & Meyer-ter-Vehn, J. (2004). Physics of inertial fusion. Oxford: Clarendon Press.
  • 4. Badziak, J., Makowski, J., Parys, P., Ryć, L., Wołowski, J., Woryna, E., & Vankov, A. B. (2001). Intensity-dependent characteristics of a picosecond laser-produced Cu plasma. J. Phys. D-Appl. Phys., 34, 1885–1891. DOI: S0022-3727(01)19985-7.
  • 5. Torrisi, L., Foti, G., Giuffrida, L., Puglisi, D., Wołowski, J., Badziak, J., Parys, P., Rosiński, M., Margarone, D., Krasa, J., Velyhan, A., & Ullschmied, U. (2009). Single crystal silicon carbide detector of emitted ions and soft X rays from power laser-generated plasmas. J. Appl. Phys., 105, 123304. DOI: 0021-8979/2009/10512/123304/7/.
  • 6. Ryć, L., Badziak, J., Juha, L., Krasa, J., Kralikova, B., Laska, L., Parys, P., Pfeifer, M., Rohlena, K., Skala, J., Słysz, W., Ullschmied, J., Wegrzecki, M., & Wołowski, J. (2003). The use of silicon photodiodes for x-ray diagnostics in the PALS plasma experiments. Plasma Phys. Control. Fusion, 45, 1079–1086. DOI: 10.1088/0741-3335/45/7/302.[Crossref]
  • 7. Woryna, E., Parys, P., Wołowski, J., & Mróz, W. (1996). Corpuscular diagnostics and processing methods applied in investigations of laser-produced plasma as a source of highly ionized ions. Laser Part. Beams, 14(3), 293–321. DOI: 0263-0346/96.
  • 8. Ryć, L., Barna, A., Calcagno, L., Foldes, I. B., Parys, P., Riesz, F., Rosiński, M., Szatmari, S., & Torrisi, L. (2014). Measurement of ion emission from plasmas obtained with a 600 fs KrF laser. Phys. Scripta, T161, 014032(5pp.). DOI: 10.1088/0031-8949/2014/T161/014032.[Crossref][WoS]